General specifications
Switching functioncomplementary
Output typePNP
Rated operating distance50 mm
Installationflush
Output polarityDC
Assured operating distance0 ... 40.5 mm
Reduction factor rAl 0.38
Reduction factor rCu 0.35
Reduction factor r304 0.83
Nominal ratings
Operating voltage10 ... 60 V DC
Switching frequency0 ... 80 Hz
Hysteresistyp. 3 %
Reverse polarity protectionreverse polarity protected
Voltage drop&le 3 V
Operating current0 ... 200 mA
Off-state current0 ... 0.5 mA
No-load supply current&le 20 mA
Operating voltage indicatorLED, green
Switching state indicatorLED, yellow
Functional safety related parameters
MTTFd670 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Approvals and certificates
UL approvalcULus Listed, General Purpose
CSA approvalcCSAus Listed, General Purpose
CCC approvalCertified by China Compulsory Certification (CCC)
Ambient conditions
Ambient temperature-25 ... 70 °C (-13 ... 158 °F)
Mechanical specifications
Connection typescrew terminals
Information for connectionA maximum of two conductors with the same core cross section may be mounted on one terminal connection!
tightening torque 1.2 Nm + 10 %
Core cross-sectionup to 2.5 mm2
Minimum core cross-sectionwithout wire end ferrule 0.5 mm2 , with connector sleeves 0.34 mm2
Maximum core cross-sectionwithout wire end ferrule 2.5 mm2 , with connector sleeves 1.5 mm2
Housing materialPBT
Sensing facePBT
Degree of protectionIP67
Equipment protection level Gc (nA)
CertificatePF 15CERT3754 X
Special conditions
Protection against transientsEnsure transient protection is provided and that the maximum value of the transient protection (140% of 85 V) is not exceeded.
Equipment protection level Dc (tc)
InstructionManual electrical apparatus for hazardous areas
Device category 3Dfor use in hazardous areas with combustible dust
CertificatePF 15CERT3774 X
CE marking[*PD-Z02586A*]
ATEX markingEx-Hexagon II 3D Ex tc IIIC T80°C Dc
The Ex-related marking can also be printed on the enclosed label.
StandardsEN 60079-0:2012+A11:2013, EN 60079-31:2014
Protection by enclosure tc Some of the information in this instruction manual is more specific than the information provided in the datasheet.
GeneralThe corresponding datasheets, declarations of conformity, EC-type examination certificates, certifications, and control drawings, where applicable (see datasheets), form an integral part of this document. These documents can be found at www.pepperl-fuchs.com. The maximum surface temperature of the device was determined without a layer of dust on the apparatus. Some of the information in this instruction manual is more specific than the information provided in the datasheet.
Installation, commissioningLaws and/or regulations and standards governing the use or intended usage goal must be observed. If the Ex-relevant identification is printed exclusively on the adhesive label provided, this label must be affixed in the immediate vicinity of the sensor! The background surface to which the adhesivelabel is to be applied must be clean and free from grease! The applied label must be durable and remain legible, with due consideration of the possibility of chemical corrosion! After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again.
MaintenanceNo changes can be made to apparatus, which are operated in hazardous areas.
Repairs to these apparatus are not possible. After opening the housing, you should check that the seal is in the correct position and is clean and intact before closing the housing again.
Special conditions
Maximum operating current ILThe maximum permissible load current must be restricted to the values given in the following list.
High load currents and load short-circuits are not permitted.
Maximum operating voltage UBmaxThe maximum permissible operating voltage UBmax must be restricted to the values given in the following list. Tolerances are not permitted.
Maximum permissible ambient temperature TUmaxdependant of the load current IL and the max. operating voltage UBmax
Information can be taken from the following list.
at UBmax=60 V, IL=200 mA44 °C (111.2 °F)
at UBmax=60 V, IL=100 mA45 °C (113 °F)
at UBmax=60 V, IL=25 mA47 °C (116.6 °F)
at UBmax=30 V, IL=200 mA50 °C (122 °F)
at UBmax=30 V, IL=100 mA53 °C (127.4 °F)
at UBmax=30 V, IL=50 mA56 °C (132.8 °F)
Protection from mechanical dangerThe sensor must not be exposed to ANY FORM of mechanical danger.
Protection from UV lightThe sensor and the connection cable must be protected from damaging UV-radiation. This can be achieved when the sensor is used in internal areas.
Electrostatic chargeElectrostatic charges must be avoided on the mechanical housing components. Dangerous electrostatic charges on the mechanical housing components can be avoided by incorporating these in the equipotential bonding. Sliding contact discharges must be avoided. Avoid electrostatic charges that can cause electrostatic discharge when installing or operating the device. Information on electrostatic hazards can be found in the technical specification IEC/TS&nbsp60079-32-1. Do not attach the nameplate provided in areas where electrostatic charge can build up. The apparatus is provided with an outer lacquered metallic screen, which must be protected from electrostatic charging.
Connections for external wireTerminal connection: Minimum conductor cross-section: 0.5 mm2, maximum conductor cross-section: 2.5 mm2. The ends of the conductor must be provided with cable sleeves.
Lead insertionIf cable glands are required for the installation then the following points must be observed: The cable glands must be certified in accordance with the application. The temperature range of the cable glands must be selected according to the application. The degree of protection must not be reduced by the cable glands. Seal the housing. Use a seal that meets the requirements of the application.
Plug connectorThe plug connector must not be withdrawn under voltage. The proximity switch is identified as follows: WARNING - DO NOT SEPARATE WHEN ENERGIZED. With the plug connector disconnected, soiling of the internal area must be prevented.(i.e. the area that is inaccessible when the connector is inserted)
General information
Use in the hazardous areasee instruction manuals
Category3G 3D

Характеристики

Производитель Pepperl+Fuchs

 

Важная информация

Все информационные материалы, представленные на сайте, носят справочный характер и не могут в полной мере передавать достоверную информацию о свойствах и характеристиках товара.

Фотография на сайте служит дополнительным источником для определения совместимости запчастей с Вашим оборудованием, и не может являться основным. Основной источник по совместимости запчастей - актуальная документация производителя оборудования, из которой значимой информацией для заказа являются: название запчасти и каталожный номер.

Запасные части и комплектующие подбираются самостоятельно покупателем строго по каталожным номерам из официальных деталировок производителей. В случае, если номенклатура товара совпадает с фактически поставленной, но не подходит на оборудование - в ее замене или возврате может быть отказано.

Цены на сайте имеют информационный характер и могут отличаться от цен в коммерческом предложении.

Производитель Pepperl+Fuchs
×
Для заказа продукции свяжитесь с нами любым удобным Вам способом. Или заполните онлайн-форму, и мы сразу ответим Вам в рабочее время
Елин Руслан, руководитель отдела продаж
Технический отдел
Казань, Адоратского, 34
KompKZN@promavtomatic.ru
Image